New module · Hydrogen Management

Hydrogen governed from power source to offtake.

Hydrogen runs on the same energy digital core as your hydrocarbons — the same assets, network, meters, approvals, audit trail and allocation engine — tracking every molecule's physical, commercial and carbon record at once.

Command center

Built around decisions, not charts.

Select an electrolyzer to see its specific energy consumption, capacity factor and water intensity. AI insights propose actions; a person approves them.

HYDROGEN COMMAND CENTER · Gulf Coast H₂ Hub · illustrative

10 Oct 2026 · day open

Production

31.7 t/d

Demand

30.2 t/d

Storage

284 t

Network imbalance

+0.21%

Average CI

0.62 kgCO₂e/kg

Power cost

$1.71/kg H₂

Electrolyzer fleet

SEC

55.6 kWh/kg

Capacity factor

82%

Water intensity

10.2 L/kg

Production → Compression → Pipeline → Salt cavern → Customers

AI insights · human approval required

  • ELY-03 specific energy consumption up 7.2% over 14 days — stack inspection proposed.
  • Customer A nomination deficit forecast for Thursday (−1.1 t).
  • Salt-cavern working gas covers 3.8 days of contracted demand.
  • Month-to-date CI forecast may exceed contractual 0.60 kgCO₂e/kg target.

Recommendation → proposed action → human approval → authorized service → execution → audit record.

Three ledgers, one flow

Molecule, ownership and carbon — tracked together.

Each batch carries a physical ledger (kg, Nm³, energy), a commercial ledger (owners, contracts, entitlements) and a carbon ledger (sources, kgCO₂e, certificates). Switch views to see the same batch three ways.

BATCH H2-00192

Mass
100,000 kg H₂
Standard volume
1,112,600 Nm³
Energy (LHV)
12,000 GJ
Purity
99.97 mol% — PASS

Auditable carbon intensity

Every CI figure opens to its evidence.

Method, version, sources, inputs and result are stored — never just a number. Regulatory methods such as 45VH2-GREET are versioned so rule changes don't rewrite history.

CARBON INTENSITY PROVENANCE

Production0.312
Electricity0.091
Water0.003
Compression0.021
Pipeline0.018
Storage0.009
Total (kgCO₂e/kg H₂)0.454

Method: HF360 full value chain v1.3 (45VH2-GREET and EU methods selectable, versioned). Sources: meter M-1002, power meter EM-101, certificate RE-9921, pipeline run P-1022, storage batch ST-292. Calculated and approved with a named reviewer.

Operating systems

Everything a hydrogen hub has to account for.

01

Production

Electrolyzers (PEM, alkaline, SOEC, AEM) and SMR/ATR with capture. Production runs, SEC in kWh/kg H₂, water intensity and capacity factor as first-class KPIs.
02

Network & blending

Pipelines, compressors and blend stations. The blend optimizer recommends injection to hit a target mol% within pipeline capacity and heating-value limits.
03

Storage

Salt caverns, compressed vessels and liquid H₂ — usable vs cushion inventory, boil-off, venting, and ownership and carbon-attribute inventory.
04

Quality

Samples for H₂ %, O₂, N₂, CO, CO₂, CH₄, H₂O, dew point and sulfur checked against specifications. A failed sample blocks delivery until a supervisor overrides.
05

Balance & allocation

Opening inventory + production + receipts − deliveries − fuel, vent, flare and purge ± inventory change = imbalance — by mass, volume, energy, owner, contract and carbon attribute.
06

Commercial & logistics

Contracts, nominations, entitlements, pricing, invoicing and settlement, with pipeline, truck, rail and marine logistics.

Six interconnected workflows

Physical, commercial and environmental — governed end to end.

From the hour of power bought to the kilogram invoiced, each workflow writes into the same model, audit trail and allocation engine.

01

Clean power procurement & hourly EAC matching

Proves the three pillars — temporal matching, additionality and deliverability — required for IRS 45V and EU RED III.

  • Hourly power telemetry from behind-the-meter renewables or grid nodes (MWh at the substation)
  • EAC / REC ingestion from M-RETS, ERCOT and PJM-GATS with generator COD, balancing area and generation hour
  • Matching engine locks unretired certificates to hourly consumption, checking zone and additionality window
  • Certificates retired and a verifiable provenance token linked to the production run
IRS 45VEU RED III
02

Electrolyzer dispatch & production accounting

Governs the conversion of water and power into hydrogen and oxygen, stack by stack.

  • Feedstock gate: demineralized water < 0.1 µS/cm, balance-of-plant cooling and nitrogen purge pressure
  • Economic dispatch against day-ahead / real-time LMP and contract floor prices — full, part load, hot standby or offline
  • Stack state cycling COLD_START → HOT_STANDBY → RAMPING → PRODUCING with voltage, current density, temperatures and ΔP
  • Gross H₂, O₂ and water consumption metered per hour
  • Specific energy consumption (kWh/kg H₂) for degradation tracking, with parasitic loads shared across active stacks
SEC kWh/kg H₂LMP dispatch
03

Conditioning, compression & real-gas storage inventory

Tracks purification losses, high-pressure compression and non-ideal storage behaviour.

  • Deoxidizer, dryer and PSA monitoring with tail-gas purge losses logged
  • Multi-stage compression to 30–70 barg (pipeline), 350–500 barg (tube trailers) or 700–900 barg (heavy transport)
  • Usable vs cushion inventory in salt caverns, tube banks and LH₂ tanks using GERG-2008 Z-factor
  • Boil-off, seal leakage and venting allocated to the facility loss waterfall
GERG-2008ISO 20765-2
04

Logistics, pipeline blending & custody transfer

Runs pipelines, tube-trailer fleets and marine bunkering from nomination to ticket.

  • Shipper nominations validated against capacity at injection, industrial and mobility delivery points
  • Blend-ratio and Wobbe Index enforcer (5–20 mol% H₂) throttles the injection skid before tariff limits are breached
  • Tube-trailer bay sequence: pre-fill checks, grounding, Coriolis filling with temperature-compensated cutoff
  • Digital bill of lading and custody tickets with kg, barg, reference temperature and GJ / MWh
Wobbe IndexCoriolis mass metering
05

Quality verification & off-spec quarantine

Guarantees purity for industrial and fuel-cell customers.

  • Online gas chromatographs, cavity ring-down spectrometers and lab grab samples
  • Fuel-cell poison screening: CO < 0.2 ppm, total sulfur < 0.004 ppm, H₂O < 5 ppm, plus HC, N₂ and O₂
  • Breach closes delivery valves, diverts gas to flare or recycle and locks the batch
  • Tamper-evident certificate of analysis linked to batch, lab records and parcel
ISO 14687 Grades A–ESAE J2719
06

Mass reconciliation, carbon ledger & settlement

Closes physical to financial on the same graph-based allocation engine used for hydrocarbons.

  • Network graph hydrated with period meter totals at sales, pipeline, off-take and storage points
  • Reverse back-allocation from sales points through compressors, purifiers and storage to each electrolyzer train
  • Line-pack variance and shrinkage allocated to producers and shippers by contractual entitlement
  • Physical (kg, Nm³, GJ), commercial (title, imbalances) and environmental (kgCO₂e/kg H₂) ledgers updated together
  • Ownership statements, JV balances, invoices with green premia and versioned 45V / GREET filings
45VH2-GREETThree-ledger close

One energy digital core

A new commodity, not a second system.

Users, roles, assets, network models, meters, rounds, approvals, day locking, audit, allocation and reporting stay authoritative in the core. Hydrogen extends them — and the same design carries CO₂, ammonia, RNG and LNG later.

Hydrocarbons

Field, offshore, pipeline, terminal and refining modules.

Hydrogen

Production, network, storage, quality, carbon and commercial.

CO₂ / CCUS

Capture, compression, transport and storage — on the roadmap.

Delivery roadmap

  1. P1Foundation — commodity model, hydrogen asset types, units and permissions
  2. P2Production — electrolyzers, SMR/ATR and production accounting
  3. P3Measurement & quality — metering, composition, sampling, specifications
  4. P4Network & storage — pipelines, compression, blending, storage
  5. P5Allocation — mass and energy balance, reconciliation, ownership
  6. P6Carbon — carbon ledger, CI engine, provenance, regulatory methods
  7. P7Commercial — contracts, nominations, scheduling, invoicing
  8. P8Intelligence — command center, forecasting, optimization, AI agents

Workflow on every record: draft → submitted → validated → approved → locked.

Request a demonstration

See your operations connected across the value chain.

We will scope the demonstration to the facilities you operate and the way you close today.

Request a demonstration